28
EEPROM Data Register
0x32
Bits Type Default Description
[15:0] RW 0x0000 EEPROM data. Read accesses return the last value read from
EEPROM.
EEPROM Command/Status Register
0x34
Bits Type Default Description
[8:3] WO 000000 EEPROM address.
[2:1] WO 00 Must be set to 10 for read access.
[0] WO 0 EEPROM access start bit. Writing a 1 to this bit starts EEPROM
access. The bit in the Interrupt Status Register is set to 1 when
access is complete.
Notes:
1. Read access to the EEPROM Command/Status register returns a value of 0x526X, where X is
a firmware revision number.